Steam Requirements

Steam Heat Option Only

The optional steam connection is located at the upper
right corner panel, as seen from the rear.

For washer-extractors equipped with optional steam
heat, install piping in accordance with approved
commercial steam practices. Steam requirements are
shown in Table 9.

NOTE: Failure to install the supplied steam filter
may void the warranty.

Never touch internal or external steam
pipes, connections, or components. These
surfaces can be extremely hot and will
cause severe burns. The steam must be
turned off and the pipe, connections, and
components allowed to cool before the
pipe can be touched.

SW014

WARNING

UW 2 Speed Pocket Hardmount

Steam Supply Information

Steam inlet connection, in. (mm)

1/2 (DN13) 12.7

Number of steam inlets

1

Recommended pressure, psi (bar)

30 – 80 (2.0 – 5.4)

Maximum pressure, psi (bar)

80 (5.4)

Table 9