Alto-Shaam 1220 User Manual

Page 10

Advertising
background image

COMbIThERM® ES SERIES • ELECTRIC INSTALLATION MANUAL #MN-28897 • 8.

6•10

es

31-3/8" (796mm)

34-1/16" (864mm)

17-15/16"

(456mm)

7-9/16"

(191mm)

WATER
DRAIN

33-1/8" (840mm)

4-15/16"
(125mm)

Steam

Ve

nt (T

op)

60-9/16" (1538mm)

Water Drain

(Back)

Treated Water

Intake (Bottom)

Untreated Water

Intake (Bottom)

Electrical Connection

(Bottom)

30" (761mm)

3-3/4" (95mm)

2-3/16" (56mm)

(283m

m)

6-3/8" (161mm)

41-15/16" (1064mm)

43-7/8" (1114mm)

2" (50mm)

49-1/8" (1247mm)

15-7/8"

(403mm)

13-1/2"

(343mm)

35-3/16" (893mm)

26-1/2"

(673mm)

7-9/16"

(192mm)

11-1/8"

weight

capacity

neT

285 lb

(129 kg)

Full-siZe pans: 20" x 12" x 2-1/2"

six (6)

ship

465 lb

(211 kg)

gn 1/1:
gn 2/1:

530 x 325 x 65mm
650 x 530 x 65mm

six (6)

Three (3)

craTe diMensions: (l x w x h)

53" x 45" x 49"

(1346 x 1143 x 1245mm)

halF-siZe sheeT pans:*

18" x 13" x 1"

six (6)

on wire shelVes only

72 lb (33 kg) MaXiMuM

VoluMe MaXiMuM: 45 quarts (57 liters)

installation requirements
• Oven must be installed level. • Hood installation is required.

• Water supply shut-off valve and back-flow preventer when required by local code.

electrical

(DEDICATED CIRCUIT REQUIRED)

Model

VolTage

ph

hZ

aMps

kw

awg

cord & plug

6•10ES Touch

208 – 240

1*

60

44.0 - 50.0

9.1 - 12.0

awg 6

no cord or plug

208 – 240

3

60

25.2 - 28.4/ph

9.1 - 11.7

awg 8

no cord or plug

380 – 415

3

50

14.0 - 16.3/ph

9.0 - 11.7

awg 12

no cord or plug

6•10ES

208 – 240

1*

60

40.8 - 47.0

8.5 - 11.2

awg 6

no cord or plug

208 – 240

3

60

23.5 - 27.0/ph

8.5 - 11.2

awg 8

no cord or plug

380 – 415

3

50

13.0 - 16.0/ph

8.5 - 11.2

awg 12

no cord or plug

*elecTrical serVice charge applies

water requirements

water quality minimum standards

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE (1) TREATED WATER INLET: 3/4" npT*
ONE (1) UNTREATED WATER INLET: 3/4" npT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar

WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air

gap insTalled as close To The oVen as possiBle

using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM
waTer QualiTy sTandards will Void This warranTy.
it is the responsibility of the purchaser to ensure that incoming water supply is
compliant with the specifi cations listed through adequate treatment measures.
installation of the combiguard

TM

water Filtration system is recommended, but

this system may not address all water quality issues present.

clearance requirements

Contaminant

Free chlorine

hardness

chloride

ph

alkalinity

silica

Total dissolved solids (tds)

Inlet Water Requirements (

untreated water

)

less than 0.1 ppm (mg/l)

less than 3 gpg (52 ppm)

less than 30 ppm (mg/l)

7.0 to 8.5

less than 50 ppm (mg/l)

less than 12 ppm (mg/l)

less than 60 ppm

LEFT 6" (152mm)

RECOMMENDED SERVICE ACCESS: 18" (457mm)

20" (508mm)

FROM HEAT PRODUCING EQUIPMENT

RIGHT 4" (102mm) TOP: 20" (508mm)

For air MoVeMenT

BACK 4" (102mm) BOTTOM: 5-1/8" (130mm)

For legs

counTer-Top insTallaTions MusT MainTain

4" (102mm)

MiniMuM

clearance FroM counTer surFace

* can manifold off of

one 3/4" line.

dimensions:

h x w x d

EXTERIOR:

35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm x 864mm)

EXTERIOR WITH RECESSED DOOR:

35-3/16" x 47-7/8" x 34-1/16" (893mm x 1216mm x 864mm)

INTERIOR:

17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm)

stacking combination dimensions:

h x w x d

6.10es over 6.10es

66-3/4" x 44" x 36-5/8" (1693 x 1115 x 930mm)

6.10es over 10.10es

73-1/8" x 44" x 36-5/8" (1857 x 1115 x 930mm)

6.10es over 7.14es

67" x 44" x 43" (1701 x 1115 x 1090mm)

6.10es over 10.18es

72-3/4" x 44" x 43" (1845 x 1115 x 1090mm)

Mobile option with 5" (127mm) casters will add 2" (51mm) to the overall height

6.10es over asc-4e

74" x 44" x 44-1/2" (1878 x 1115 x 1130mm)

Advertising