COMbIThERM® ES SERIES • ELECTRIC INSTALLATION MANUAL #MN-28897 • 12.

10•10

es

i

33-1/16" (840mm)

4-15/16"

(125mm)

41-1/2" (1053mm)

33-15/16" (861mm)

7-9/16" (192mm)

60-9/16" (1538mm)

Water Drain

(Back)

30" (761mm)

2" (50mm)

49-1/8" (1247mm)

43-7/8" (1114mm)

31-3/8" (796mm)

34-1/16" (865mm)

17-15/16"

(456mm)

7-9/16"

(191mm)

Water Drain

6-1/4" (158mm)

41-15/16" (1064mm)

Steam

Ve

nt (T

op)

Electrical Connection (Bottom)

Treated Water
Intake (Bottom)

Untreated Water
Intake (Bottom)

2-1/8" (53mm)

3-3/4" (95mm)

11-1/8" (283mm)

15-3/4"

(400mm)

13-1/2"

(343mm)

installation requirements
• Oven must be installed level. • Hood installation is required.

• Water supply shut-off valve and back-flow preventer when required by local code.

weight

capacity

neT

385 lb

(175 kg)

Full-siZe pans: 20" x 12" x 2-1/2"

Ten (10) eight (8)

ship

525 lb

(238 kg)

gn 1/1: 530 x 325 x 65mm

Ten (10) eight (8)

craTed diMensions: (l x w x h)

gn 2/1: 650 x 530 x 65mm

Five (5) Four (4)

53" x 45" x 49"

halF-siZe sheeT pans:*

18" x 13" x 1"

Ten (10) nine (9)

(1346 x 1143 x 1245mm)

on wire shelVes only

120 lb (54 kg) MaXiMuM

VoluMe MaXiMuM: 75 quarts (95 liters)

*addiTional wire shelVes reQuired For MaXiMuM capaciTy

electrical

(DEDICATED CIRCUIT REQUIRED)

combismoker®

Model

VolTage

ph

hZ

aMps

kw

awg

cord & plug

additional kw

10•10ESi Touch

208 – 240

1*

60

77.0

18.4

awg 3

no cord or plug

+ .5 kw

208 – 240

3

60

44.3/ph

18.4

awg 6

no cord or plug

+ .5 kw

380 – 415

3

50

25.6/ph

18.4

awg 10

no cord or plug

+ .5 kw

440 – 480

3*

60

22.0/ph

18.4

awg 8

no cord or plug

+ .5 kw

10•10ESi

208 – 240

1*

60

77.0

18.4

awg 3

no cord or plug

+ .5 kw

208 – 240

3

60

44.3/ph

18.4

awg 6

no cord or plug

+ .5 kw

380 – 415

3

50

25.6/ph

18.4

awg 10

no cord or plug

+ .5 kw

440 – 480

3*

60

22.0/ph

18.4

awg 8

no cord or plug

+ .5 kw

*electrical service charge applies

water requirements

water quality minimum standards

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE (1) TREATED WATER INLET: 3/4" npT*
ONE (1) UNTREATED WATER INLET: 3/4" npT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar

WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air

gap insTalled as close To The oVen as possiBle

using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM
waTer QualiTy sTandards will Void This warranTy.
it is the responsibility of the purchaser to ensure that incoming water supply is
compliant with the specifi cations listed through adequate treatment measures.
installation of the combiguard

TM

water Filtration system is recommended, but

this system may not address all water quality issues present.

clearance requirements

Contaminant

Free chlorine

hardness

chloride

ph

alkalinity

silica

Total dissolved solids (tds)

Inlet Water Requirements (

untreated water

)

less than 0.1 ppm (mg/l)

less than 3 gpg (52 ppm)

less than 30 ppm (mg/l)

7.0 to 8.5

less than 50 ppm (mg/l)

less than 12 ppm (mg/l)

less than 60 ppm

LEFT 6" (152mm)

RECOMMENDED SERVICE ACCESS: 18" (457mm)

20" (508mm)

FROM HEAT PRODUCING EQUIPMENT

RIGHT 4" (102mm) TOP: 20" (508mm)

For air MoVeMenT

BACK 4" (102mm) BOTTOM: 5-1/8" (130mm)

For legs

counTer-Top insTallaTions MusT MainTain

4" (102mm)

MiniMuM

clearance FroM counTer surFace

* can manifold off of

one 3/4" line.

dimensions:

h x w x d

EXTERIOR:

41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x 865mm)

EXTERIOR WITH RECESSED DOOR:

41-1/2" x 47-7/8" x 34-1/16" (1053mm x 1216mm x 865mm)

INTERIOR:

27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm)