COMbIThERM® ES SERIES • ELECTRIC INSTALLATION MANUAL #MN-28897 • 3.

s i t e i n s t a l l a t i o n

i n s t a l l a t i o n

d a n g e r

IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.

c a u t i o n

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

d a n g e r

DO NOT store or use gasoline or other
fl ammable vapors or liquids in the
vicinity of this or any other appliance.

d a n g e r

AVERTISSEMENT : UNE INSTALLATION,
UN AJUSTEMENT, UNE ALTÉRATION,
UN SERVICE OU UN ENTRETIEN NON
CONFORME AUX NORMES PEUT CAUSER
DES DOMMAGES À LA PROPRIÉTÉ, DES
BLESSURES OU LA MORT.

LIRE ATTENTIVEMENT LES DIRECTIVES
D’OPÉRATION ET D’ENTRETIEN
AVANT DE FAIRE L’INSTALLATION, OU
L’ENTRETIEN DE CET ÉQUIPEMENT.

s i t e i n s t a l l a t i o n

installation codes
& standards

The following codes and standards are required
for installation of this oven: air supply,
elecTrical connecTions, waTer
connecTions, and wasTe waTer
discharge.

note:

where automatically operated appliances are
vented through a ventilating hood or exhaust
system equipped with a damper or with a power
means of exhaust, provisions shall be made to
allow the equipment to operate only when the
damper is open to a position to properly vent the
appliance and when the power means of exhaust
is in operation.
in accordance with nFPa 54
commonwealth oF massachusetts only.

ventilation requirements

a steam ventilation hood is mandatory for the
operation of the oven. The ventilation hood must
be installed in accordance with local building codes
for the steam exhaust and must protrude 12-inches
to 20-inches (300 to 500mm) over the front side of
the oven. a grease filter must be located in the
protruding area of the hood. grease filters should
be thoroughly cleaned on a regular basis following
manufacturer's instruction. Ventilation hoods must
ensure an adequate amount of incoming air during
operation and must be operated whenever the
combination oven/steamer is used in order to avoid
the accumulation of condensation in the hood area.