Advanced chipset features, Mps version control for os, Os select for dram > 64mb – Albatron Technology KI51PV-754 User Manual

Page 29: Hdd s.m.a.r.t. capability, Small logo (epa) show, Dram configuration

Advertising
background image





Mainboard KI51PV-754

25

APIC stands for Advanced Programmable Interrupt Controller, and is used to extend the

number of available IRQs available in order to avoid sharing conflicts.
Options: Disabled, Enabled (Default).

MPS Version Control For OS

The 1.1 version is the older version that supports 8 more IRQs in the Windows NT environment.

Choose the new 1.4 version for Windows 2000 and Windows XP. Options: 1.4 (Default), 1.1.

OS Select For DRAM > 64MB

Select “OS2” only if you are running the OS/2 operating system with greater than 64 MB of RAM.

Options: Non-OS2 (Default), OS2.

HDD S.M.A.R.T. Capability

The SMART (Self Monitoring Analysis and Reporting Technology) technology enables a PC to

attempt to predict the possible failure of storage drives. Options: Disabled (Default), Enabled.

Small LOGO (EPA) Show

This option allows you to show or hide the small LOGO EPA.
Options: Disabled (Default), Enabled.

Advanced Chipset Features

DRAM Configuration

Timing Mode

This option determines DRAM clock/ timing using SPD or manual configuration.
Make sure your memory module has SPD (Serial Presence Data) if you want to use the “By
SPD” option. Options: Auto (Default), Manual

Memclock index value (Mhz)

This item allows you to select the memory clock. When it set to “auto”, the system will
automatically detect the memory clock. Options: 100, 133, 166, 200 (Default), 216, 233, 250

CAS# latency (Tcl)

This option determines CAS Latency. When synchronous DRAM is installed, the number of

clock cycles of CAS latency depends on the DRAM timing. Do not reset this option from the

default system manufacturer value. This option is adjustable only when “DRAM Timing

Selectable” is set to “Manual”. This option is locked when “DRAM Timing Selectable” is set to

“By SPD” and is automatically determined by the system. Options: 2, 2.5, 3 (Default)

Min RAS# active time (Tras)

This option allows you to select DRAM Active to Precharge Delay.

Options: Auto, 5T, 6T, 7T, 8T (Default), 9T, 10T, 11T, 12T, 13T, 14T, 15T

RAS# to CAS# delay (Trcd)

This option allows setting the RAS# to CAS# delay to Rd/Wr command on the same bank.