402s Ovens Pt. No. 32Z3522 Issue 6

21

Test for microwave leakage at all points marked with a


• Readings must be below 4mW/cm². If a level greater that 4mW/cm² is observed,

this should be reported to Merrychef Service Division immediately.


• In any case, notes should be kept of the leakage that is observed. In terms of level and

position on the oven. This should be kept with the service documentation.

PROCEDURE FOR MICROWAVE EMISSION TEST (2)

Control Panel

Door Perimeter

Rear Cover/ vents

Door Perimeter