Procedure for power output measurement, Ensure the oven is cold before commencing the test – Merrychef 402s User Manual

Page 22

Advertising
background image

402s Ovens Pt. No. 32Z3522 Issue 6

22

PROCEDURE FOR POWER OUTPUT MEASUREMENT

The power output specification 1500W on this model is established under IEC 705 standard
method. This method is only workable in Laboratory controlled conditions.

An approximate method is as follows:

1. Fill one beaker ( glass or plastic ) with 2.11 pints ( one litre ) of tap water

at about 68ºF ( 20ºC ) and measure the water temperature.
( Use a thermometer with a

1

/

10

, 0.1 degree gauge ).

2. Place the beaker in the centre of the cold cavity.

3. Version 2.0 Press the Manual Function Pad to enter Manual Mode

Version 3.0 Press the lower RH function pad below the display to enter

Manual Mode

Set

Time to 1 minute 3 seconds, Power to 100% and Fan to 0%.

Press the Start pad and wait until the counter reaches zero.

4. Take the beaker out immediately stir the water with a plastic implement

and measure the water temperature.

Calculate the temperature rise of water in the beaker.
The temperature rise of the water should be within the following range:

Temperature Rise

27ºF ( 15ºC ) Minimum

36ºF ( 20ºC ) Maximum

Ensure the oven is cold before commencing the test

Note:
Power Output is affected by the line voltage under load.
For correct Power Output measurement the line voltage under load must be correct.

Test procedure:

Changing the Oven Profile

In order to carry out the test the oven PREHEAT
must be set to OFF[ V3.0 ] or 0ºF[ V2.0 ] to switch
off the convection heaters and the Manual
controls must be set to ON [ V3.0 ] or PROGRAM/
MANUAL
[ V2.0 ]
When the test is completed the oven must be
returned to its original settings or the appropriate
MenuKey can be used to reset the oven
automatically.
See Appendix 6 for changing the Oven Profile

Manual Mode
If the manual mode
screen does not
appear it must be
changed in the
OVEN PROFILE see
Appendix 6

Advertising