402s Ovens Pt. No. 32Z3522 Issue 6

32

Check Current using clip on current
meter through F7 and F8. When
running Microwave only. You will
need to reset the pre-heat
temperature to 0 and enable manual
control via the profile setting. Make
sure that there is a water load in
the cavity.



Check that the

stirrer is rotating.


Replace stirrer motor

and retest

Carry out Microwave Output Test

Check Microwave Generating system


• Transformer
• Magnetron

• Capacitor

• Diode

Possible Temperature Sensor Fault.
Assuming sensor Ok then make sure
door Light on logic PCB is on when
door closed. If this is working then
replace Logic PCB.

Also, check that convection motor is
operational

Contact Merrychef Service
Department for Further
assistance.

Cold Food

Check Convection

Temperature control

OK

NO

Less than
5 Amps

More than
5 Amps

No

Yes

LOW

OK