Principal components: hot air motor & controller 2 – Merrychef 402s User Manual

Page 28

Advertising
background image

402s Ovens Pt. No. 32Z3522 Issue 6

28

LED

Meaning

Position

LED Off

Inverter Off / No supply

Long On & Off (1sec)

Power On / Ready

LED On steadily

Inverter Running

Long On (0.5 sec)/ short Off General Warning

Very Short On & Off (0.1sec) Fault Condition

Displays and messages: LED status display

PRINCIPAL COMPONENTS: Hot Air Motor & Controller 2

LED

Power Terminals

Motor Terminals

Motor Controller

Provides an AC, 3-phase switched mode drive to
the convection motor and is controlled by a 0 - 10
Volt signal from the logic board. This allows the
motor to be adjusted from approximately 1500
rpm to 7000 rpm in steps of 5%.

Door Open

= 1500 RPM

Door Closed (not cooking) = 3500 RPM
Door Closed (cooking)

= as specified by

program or setting

Blue Black Brown

Wire
27

Wire 26

Fan
speed %

Voltage

dc

RPM Condition

100% 10V 7000

Full
Speed

50% 5V 3000

Door
Closed

20% 2V 1500

Door
Open

Grey wire
to Motor

Blue 0V

Yellow 0-10V

Red +10V

V

Motor Speed and Logic board voltage table