Warning, Objective, Method of adjustment – Merrychef 402s User Manual

Page 26: Procedure

Advertising
background image

402s Ovens Pt. No. 32Z3522 Issue 6

26

WARNING

Before adjusting the microswitch

assemblies ensure that the oven

has been isolated from the

electrical supply.

Please note the terminals on the

microswitches remain live when

the oven is switched off, so

complete isolation is essential.

Objective


With a 1mm spacer located as shown, both
switches on both sides should be activated/ closed
position.

With a 5mm spacer located as shown SW2 and
SW3 should be open.

Method of adjustment.


By loosening the four screws on each mounting
bracket the microswitch assembly can be raised or
lowered and thereby the switches can be made to
operate at different door positions.

Procedure.


1. Isolate the oven from the Electrical supply.

2. Place a 1mm spacer between the cavity face

and the door seal as shown.

3. Working on the right hand side, adjust the

bracket so the SW2 ‘just’ operates.

4. Working on the left hand side, adjust the

bracket so that SW3 ‘just’ operates.

5. Remove the 1mm spacer and then place a

5mm spacer in the same position.
Check that SW2 and SW3 are open circuit and
not operated.

6. Repeat the steps above to ensure the setup is

correct.

7. Ensure that all the screws are tightened.
8. Reconnect

the

electrical

supply.

PROCEDURE FOR DOOR INTERLOCK ADJUSTMENT AND TEST 2

It is vital that the microswitches are adjusted to the correct position. There are two sets
switch assemblies located either side of the oven.

The interlocks ensure that the oven will not operate microwave with the door open.

Spacer

Door seal

Door

Advertising