Installation Instructions for Mealstream Combination Ovens

Power Supply Requirements

The Mealstream Series should be connected to a suitable electricity supply, which can cope
with the switching-on surge that occurs with certain types of catering equipment, including
microwaves. Because of this requirement, we strongly recommend that a separate, suitably
rated supply is installed for the oven.

The supply for the oven should be fitted with a Type "C" or Time Delay circuit breaker.


If the oven is hard-wired to the supply, a double-pole isolator switch with a contact gap of at
least 1/8 inch ( 3 mm ) should be fitted.

Positioning the Oven


In order to maintain adequate ventilation for air intake
and exhaust, and to allow access for cleaning filters,
you must allow a minimum of 2 inches ( 50 mm )
clearance at the sides and rear of the oven.

Air intake temperature should not exceed 110°F/45°C
excessive temperature will lead to reduced operating duty
cycle, or premature ageing of internal components.
Failure to comply with these conditions will invalidate the
warranty.

Note:
The minimum recommended
clearance required for air flow

Grounding requirement

This appliance must be connected to a grounded, metallic, permanent wiring system, or an
equipment grounding conductor should be run with the circuit conductors and connected to the
equipment grounding terminal or lead on the appliance.

INSTALLATION INSTRUCTIONS

NEVER Install an oven above fryers,

grills, griddles or any other
major heat source.


ALWAYS Place containers in the cavity

carefully - impact damage
may chip the vitreous enamel
coating on the runners and
baffle plate.