Testing the components, Check for leaks, Check the electrical installation – Power Soak 29222 INSTRUCTIONS INSTALLATION PS-200 User Manual

Page 26: Check operation, Check the chemical dispensing system

Advertising
background image

22

Testing the Components

Check for Leaks

• Turn on the water supply and inspect all joints for leaks.
• Close the drain valve(s), fill the sink(s) with water and inspect the

drain fittings for leaks.

• Open the drain valve(s) and inspect the drain joins for leaks as the

water is draining from the sink.

Check the Electrical Installation

• Verify that there are no loose wires or open electrical enclosure.
• Fill the wash tank with water and press the START button to see

that the motor will start. Have a qualified electrician verify that the
amp draw on the electrical supply is within the specifications on the
identification tag.

• Check motor rotation for the correct direction as indicated by the

arrow on the pump housing.

Check Operation

• Open each faucet knob and verify that water flows from each hand

control. Verify that hot and cold water are running from the correct
hand control.

• With the water valves open, turn the center knob to see that it will

shut off flow to the faucet and that the hand sprayer is still
functional.

Check the Chemical Dispensing System

The Chemical Dispensing System must be checked by a representative of
the manufacturer. It will need to be verified that the proper amount of
chemical is being dispensed and that the proper chemical concentration is
maintained during operation.

MOTOR ROTATION

MUST BE THE

CORRECT DIRECTION

FOR THE MACHINE TO

OPERATE CORRECTLY

IMPORTANT

Direction of
rotation arrow

Advertising