Pre-Plumbing

Supply and Waste Lines

The supply and waste lines must meet the following requirements:

• Hot and cold water supply must be ½” diameter or larger.
• Center lines of the hot and cold water supply must be 10” or less above

the floor to access the shutoff valves when the machine is installed.

• Waist drain must be 1-1/2” minimum diameter.
• Center line of the waste drain must be 11” or less above the floor to

allow the sink to drain properly.


Install new shutoff valves on the hot and cold water supply lines.







Grease Trap

It may be necessary to relocate and/or replace the existing grease trap. Be
sure that the grease trap meets or exceeds the local plumbing codes.








IT IS RECOMMENDED THAT ALL MACHINES BE INSTALLED USING

NEW ½” OR LARGER BALL-VALVE SHUT OFF VALVES.

IMPORTANT

WASTE PLUMBING MUST CONFORM TO LOCAL BUILDING CODES.