Rear Panel Connections with Callouts

Image: ZoomSHOT HD Camera

1) RS-232 & IR Out: The RS-232 accepts modified VISCA protocol for camera control, as well as transmits IR
signaling received by the front IR receiver, which can be transmitted to third party devices. The ZoomSHOT will
not react to the remote if the IR is off. IR forwarding is only available in the SR Quick-Connect models.

2) EZ Power/Video Port:
This RJ-45 connector is only used with the Quick-Connect SR, Quick-Connect DVI-D/HDMI SR Interface, Quick-
Connect USB and USB Mini Interfaces to supply power and return HSDS (differential) video from the camera
over Cat-5 cable up to distance of 150’ (45.72m).

3) ZoomSHOT Dip Switch Settings:
Settings for IR remote frequency, IR receiver on/off, image flip, test bars and Defaults can be configured on these
switches. See the Switch Settings page for additional information. The dip switch settings are as follows:

Table: ZoomSHOT Dip Switch Settings

4) HD Video Select:
A rotary switch allows the user to choose the component HD output video resolution and format. After setting or
changing the resolution, reboot the camera to ensure proper operation. If an unassigned rotary selection position
is chosen (3, 9, A, B, C or D), the camera will output a medium grey video privacy mask. Simply set the rotary
switch to an assigned position to output video. The HD Video Select Rotary Switch Settings are as follows:

Table: ZoomSHOT HD VIDEO Selections

Dip Switch

Function

1

Up = IR1, Down = IR2

2

Up = IR 1 or 2, Down = IR3

3

Up=IR ON, Down = IR OFF

4

Up = Normal Image, Down = Image Flip

5

Test Bars

6

Update Position - Leave UP unless updating firmware

All Down

Reset to Defaults - with power cycle

Rotary

Resolutions

Rotary

Resolutions

0

720p/59.94

8

576p/5

0

1

1080i/59.94

9

--

2

1080p/59.94

A

--

3

--

B

--

4

720p/50

C

--

5

1080i/50

D

--

6

1080p/50

E

1080p/29.97

7

480p/59.94

F

1080p/25

Notes:

1)

For IP or USB 2.0 Streaming, use
position “0” (720p/59.94) for best results

2)

Set the rotary switch to an assigned
position. A medium grey privacy mask is
displayed on unassigned positions.

Point the notch in
the switch stem to
assign the rotary
position

Advertising