Goulds Pumps XHD - IOM User Manual

Page 10

Advertising
background image

Introduction and Safety

Guidelines for compliance

Compliance is only fulfilled when the pump is operated within its intended use, for example
within its intended hydraulic range. The conditions of the service must not be changed without
approval of an authorized ITT representative. When installing or maintaining explosion-proof
pumps, follow these guidelines:

• Always install ATEX-approved equipment in compliance with the directive and applicable

standards (IEC/EN 60079–14).

• Do not install explosion proof products in locations that are classified as hazardous in the

national electric code, ANSI/NFPA 70–2005.

WARNING:
This manual clearly identifies accepted methods for disassembling units. These methods must be
adhered to. Trapped liquid can rapidly expand and result in a violent explosion and injury. Never apply
heat to impellers, propellers, or their retaining devices to aid in their removal unless explicitly stated in this
manual.

If there are any questions regarding these requirements, the intended use, or if the equipment
requires modification, contact an ITT representative before you proceed.

Personnel requirements

ITT disclaims all responsibility for work done by untrained and unauthorized personnel.
These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:

• All work on the product must be carried out by certified electricians and ITT-authorized

mechanics. Special rules apply to installations in explosive atmospheres.

• All users must know about the risks of electric current and the chemical and physical

characteristics of the gas and/or vapor present in hazardous areas.

• Any maintenance for Ex-approved products must conform to international and national

standards (for example IEC/EN 60079-17).

Product and product handling requirements

These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:

• Only use the product in accordance with the approved motor data stated on the

nameplates.

• The Ex-approved product must never run dry during normal operation. Dry running during

service and inspection is only permitted outside the classified area.

• Never start a pump without the proper priming.

• Before you start working with the product, make sure that the product and the control panel

are isolated from the power supply and the control circuit, so they cannot be energized.

• Do not open the product while it is energized or in an explosive gas atmosphere.

• Make sure that thermal contacts are connected to a protection circuit according to the

approval classification of the product.

• Intrinsically safe circuits are normally required for the automatic level-control system by the

level regulator if mounted in zone 0.

• The yield stress of fasteners must be in accordance with the approval drawing and the

product specification.

• Make sure that the equipment is properly maintained:

• Monitor the pump components and the end temperature of the liquid.

• Maintain proper bearing lubrication.

• Do not modify the equipment without approval from an authorized ITT representative.

• Only use parts that have been provided by an authorized ITT representative.

8

XHD Installation, Operation, and Maintenance Manual

Advertising