Remove the expeller (optional feature) – Goulds Pumps XHD - IOM User Manual

Page 77

Advertising
background image

Maintenance

3. Move the casing volute liner (561) out of and away from the gland half casing.

4. Remove the seal cover-to-volute liner gasket (351Q).
5. Remove the volute liner retention studs (356K) from the casing volute liner (561) using a

metric stud driver.

Remove the expeller (optional feature)

1. Remove the impeller hub o-ring (412U).
2. Remove the expeller (263) from the shaft (122).

XHD Installation, Operation, and Maintenance Manual

75

Advertising