Alignment measurement guidelines, Attach the dial indicators for alignment, Pump-to-driver alignment instructions – Goulds Pumps XHD - IOM User Manual

Page 32

Advertising
background image

Installation

Alignment measurement guidelines

Guideline

Explanation

Rotate the pump coupling half and the driver

This prevents incorrect measurement.

coupling half together so that the indicator rods
have contact with the same points on the driver
coupling half.
Move or shim only the driver in order to make

This prevents strain on the piping installations.

adjustments.
Make sure that the hold-down bolts for the driver

This keeps the driver stationary since movement

feet are tight when you take indicator measure-

causes incorrect measurement.

ments.
Make sure that the hold-down bolts for the driver

This makes it possible to move the driver when you

feet are loose before you make alignment correc-

make alignment corrections.

tions.
Check the alignment again after any mechanical

This corrects any misalignments that an adjustment

adjustments.

may have caused.

Attach the dial indicators for alignment

You must have two dial indicators in order to complete this procedure.
1. Attach two dial indicators on the pump coupling half (X):

a) Attach one indicator (P) so that the indicator rod comes into contact with the perimeter

of the driver coupling half (Y).
This indicator is used to measure parallel misalignment.

b) Attach the other indicator (A) so that the indicator rod comes into contact with the inner

end of the driver coupling half.
This indicator is used to measure angular misalignment.

2. Rotate the pump coupling half (X) in order to check that the indicators are in contact with

the driver coupling half (Y) but do not bottom out.

3. Adjust the indicators if necessary.

Pump-to-driver alignment instructions

Perform angular alignment for a vertical correction

Before you start this procedure, make sure that the dial indicators are set up correctly.
1. Set the angular alignment indicator to zero at the top-center position (12 o’clock) of the

driver coupling half (Y).
A unit is in angular alignment when the angular indicator (A) does not vary by more than
0.004 in (0.10 mm) as measured at 4 points 90º apart at the operating temperature.

2. Rotate the indicator to the bottom-center position (6 o’clock).
3. Record the indicator reading.

30

XHD Installation, Operation, and Maintenance Manual

Advertising