Goulds Pumps XHD - IOM User Manual

Page 53

Advertising
background image

Commissioning, Startup, Operation, and Shutdown

1. De-energize the motor, place the motor in a locked-out position, and place a caution tag at

the starter that indicates the disconnect.

2. Put the pump-side end plate in place.

If the pump-side end plate is already in place, make any necessary coupling adjustments
and then proceed to the next step.

3. Put the pump-half of the coupling guard in place:

a) Slightly spread the bottom apart.
b) Place the coupling guard half over the pump-side end plate.

1. Annular groove
2. Pump-side end plate
3. Driver
4. Pump half of the coupling guard

The annular groove in the coupling guard half must fit around the end plate.

1. Annular groove
2. End plate (pump end)
3. Guard half

4. Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate.

Tighten securely.

XHD Installation, Operation, and Maintenance Manual

51