Method 2, Method 3, Method 2: method 3 – ATEN NETTM SN0108 User Manual

Page 100

Advertising
background image

SN0108 / SN0116 User Manual

90

4. Select either Obtain an IP address automatically (DHCP), or Specify an

IP address. If you chose the latter, fill the IP Address, Subnet Mask, and
Gateway fields with the information appropriate to your network.

5. Click Set IP.

6. After the IP address shows up in the Device List, click Exit to end the

program.

Method 2:

1. Set your computer's IP address to 192.168.0.XXX

Where XXX represents any number or numbers except 10. (192.168.0.10 is
the default address of the SN0108 / SN0116.)

2. Specify the switch's default IP address (192.168.0.10) in your browser, and

you will be able to connect.

3. Assign a fixed IP address for the SN0108 / SN0116 that is suitable for the

network segment that it resides on.

4. After you log out, be sure to reset your computer's IP address to its original

value.

Method 3:
A fixed IP address can also be assigned with the ARP command as follows:

1. Turn off the power to the SN0108 / SN0116.

2. Enter the following command:

arp -s <ip address> <SN0108 / SN0116's MAC address>

Where the IP address that you assign is one suitable for the network
segment that the SN0108 / SN0116 resides on.

Note: The SN0108 / SN0116's MAC address can be found on its bottom

panel.

3. Turn the power to the SN0108 / SN0116 back on.

sn816.book Page 90 Thursday, December 13, 2007 5:16 PM