Chapter 6. Out of Band Operation

65

Indirect PPP Connection

This method uses a modem connection to phone into the SN0108 / SN0116
from a remote location.

Setup:

1. Set up your hardware configuration to match the diagram, below:

Š On the remote computer side, use a standard 9 pin serial modem cable

(pin 2 to pin 2; pin 3 to pin 3) to connect the computer to the modem.

Š On the SN0108 / SN0116 side, use Cat 5 cable and an RJ-45 to Serial

adapter to connect a modem to any of its serial ports (see theSN0108D
/ SN0116D PC Installation Diagram:
, page 14).
Also see RJ-45 to
Serial Adapters
, page 92, for
details on choosing the appropriate
adapter. The usual choice for connecting to a modem is SA0142.

Note: Be sure that the port you specify as the Console Port in the OOBC

dialog box (see p. 28) matches the port that you connect the modem
to. Change the setting, if necessary.

2. Set up your connection configuration as specified in Steps 2 - 8 of the

Direct Dial In Connection, section (see page 61).

3. For Step 9, key in the SN0108 / SN0116's modem telephone number in the

fields provided, then click Next.

4. Click Finish.

A new icon that you can use to connect to the SN0108 / SN0116 is created
in the Dial-up Network folder. This completes the Indirect Dial In setup.

Remote

Operator

Modem

Modem

Phone Line

SN0108 / SN0116

Serial Modem Cable

Ethernet Cable

DTE to DCE

Adapter