Page 35 of 48

Issue 1031

Indoor Blower Speeds

1. When the thermostat is set to “FAN ON”, the indoor

blower will run continuously on the heating speed when

there is no cooling or heating demand.

2. When the furnace is running in the heating mode, the

indoor blower will run on the heating speed.

3. When there is a cooling demand, the indoor blower will

run on the cooling speed.

Generator Use - Voltage Requirements

The furnace requires 120 volts ± 10% (Range: 180 volts

to 132 volts)

The furnace operates at 60 Hz ± 5% (Range: 57 Hz to

63 Hz)

The furnace integrated control requires both polarity and

proper ground. Both polarity and proper grounding

should be checked before attempting to operate the

furnace on either permanent or temporary power.

Generator should have a wave form distortion of less

than 5% RHD

terminals. If a humidifier rated at greater than one amp is

connected to this terminal, it is necessary to use an external

relay. See Figure 54 for control board configuration. This

terminal is energized in the heating mode when the

combustion air inducer is operating.

Install the room thermostat according to the instructions

provided with the thermostat. See Figure 51 for thermostat

designations. If the furnace is being matched with a help

pump, refer to the FM21 installation instruction or appropriate

dual fuel thermostat instructions.

FURNACE & CONDENSING UNIT

THERMOSTAT DESIGNATIONS

(Refer to specific thermostat and outdoor unit.)

Figure 51

TYPICAL FIELD WIRING DIAGRAM

Figure 52

WARNING:

ELECTRIC SHOCK HAZARD, CAN CAUSE INJURY

OR DEATH. UNIT MUST BE GROUNDED IN

ACCORDANCE WITH NATIONAL AND LOCAL CODES

NOTE:

IF ANY WIRE IN THIS APPLIANCE IS REPLACED, IT

MUST BE REPLACED WITH WIRE OF LIKE SIZE,

RATING, INSULATION THICKNESS AND

TERMINATION

FIELD SUPPLIED ACC. WIRE

S145 IS USED WITH HONEYWELL GAS VALVE

WHEN APPLIED IN LP GAS UNITS

Advertising