Activate alarms – In-Situ Tube 300R Telemetry System User Manual

Page 13

Advertising
background image

800-446-7488

13

www.in-situ.com

4. Enter up to 2 phone numbers in the fields under "SMS" to receive Tube status

updates and alerts via text messages. In-Situ Inc. SIM cards do not support text
message alerts
.

5. To receive data or alerts using email, enter the SMTP server for your email or

internet service provider. If your provider requires a user name and password, enter
those in the fields under the SMTP server. In-Situ Inc. SIM cards do not support
SMTP data or alerts
.

6. Enter the email address you'd like to receive the email from (must be a valid

address), the address to receive email, and a carbon copy address if desired.

7. If you are using FTP to receive data, fill in all the fields of the FTP parameters

section. "CSV" and "TXT" are the only options for file type.

8. Click Write options and parameters.

9. Close the window.

Activate Alarms

1. Click General information, parameters and functional options.

2. Click the Alarms tab.

3. Select the alarms you wish to activate. To activate alarms that are dependent on

probe parameter readings, select "Reading from probe out of range."

4. Under the "Alarm options" heading, select whether to send alarms using SMS (text)

messages when they occur, then select whether to send alarm statuses each time
the Tube sends measurement values.

5. Enter the number of consecutive times a parameter in Absolute alarm mode can

exceed it's threshold before an SMS message is generated. A value of 1 means an
SMS message is generated every time.

6. Enter the number of consecutive times a parameter in Incremental alarm mode can

exceed it's threshold before an SMS message is generated. A value of 1 means an
SMS message is generated every time.

7. Enter the maximum number of text messages to be sent for the same Alarm

episode.

8. Enter the maximum number of alarms that can be sent per day.

9. Click Write alarm parameters.

10. Close the window.