Mv minimum velocity<value – RMS Technologies R101 DRIVER/INDEXER User Manual

Page 26

Advertising
background image

RMS Technologies

Page 26

Version 1.31

R101 Single Axis Driver/Indexer Manual

10/1/2007

MV

Minimum Velocity<value>


Command or Query 250 to 15,000.


Reads or sets the minimum velocity for both Position and Velocity command moves


The units are steps (at the current Step Resolution) per second

Command Example

#AMV500<cr><lf> Sets Minimum Velocity to 500 SPS

Default value is 250


NOTE: Since the R101 follows a trapezoidal motion profile, the minimum velocity
must be less than the Velocity Limit. The R101 will accelerate from MV to VL then

decelerate down to MV. (#AMV < #AVL)

Advertising