10/1/2007

VL

Velocity Limit<value>


Command or Query 250 to 15,000


Reads or sets the velocity used for the constant velocity portion of a position move.


Command Example

#AVL5000<cr><lf> Sets the velocity limit to 5000 PPS.

Default value is 15,000


NOTE: Since the R101 follows a trapezoidal motion profile, the minimum velocity

must be less than the Velocity Limit. The R101 will accelerate from MV to VL then
decelerate down to MV. (#AMV < #AVL)