38 SawStop 10” Contractor Saw

Preparing Your Saw for Use

Prepare your new power cord by cutting about 6

1

2

inches

of the cable housing off of one end of the cord so that

you have access to the three insulated wires in the power

cord. Strip off the insulation at the tips of each of the three

wires and secure terminal forks at the end of the white and

black wires and a ring terminal on the green wire (see

Fig. 39). Make sure the connections are secure and not

loose and that none of the wires are left uninsulated below

the terminal fork or ring.

Changing the Plug or Power Cord on a 208-240V Saw

Replacing the Power Cord Plug

The 230V contactor box assembly (CNS-WA-014) which enables the contractor saw to be used with 230V

power comes with a NEMA 6-15P plug attached to the end of a 9 ft power cord. If you need to replace the plug

with a different style plug, replace it with a 3-prong, 208-240V, UL-listed plug. There are numerous styles of

208-240V plugs, so select a plug that matches the single phase 208-240V power outlet from which you intend

to power the saw. Connect the white and black wires to the two “hot” plug terminals. Connect the green wire to

the ground plug terminal. Follow the manufacturer’s specific wiring instructions that come with your 208-240V

plug.

Table 2

Minimum Cord Gauge

for 208-240V

Length

Gauge

0 - 50 Feet

16 AWG

50 - 100 Feet

14 AWG

100 - 200 Feet

12 AWG

WARNING! Loose electrical connections can cause fires.

Replacing the 230V Power Cord

You may replace the 9 ft power cord that came attached

to your 230V contactor box assembly with a longer cord.

If you replace the cord, use a 3-conductor cable heavy

enough to carry enough current for the motor. A cord that

is undersized or too long can cause a voltage drop that will

decrease the power supplied to the motor and could result

in overheating. See Table 2 for the minimum recommended

cord length and gauge for 208-240V power.

WARNING! Make sure the saw is unplugged from the wall

outlet before proceeding with the following instructions.

contactor box

white

green

black

power

cord

Fig. 39

Fig. 40

Locate the contactor box which is mounted to the back side of

the switch box bracket (see Fig. 40).