Preparing your saw for use, 230v contactor box wiring diagram – SawStop CNS175-AU User Manual

Page 42

Advertising
background image

40 SawStop 10” Contractor Saw

Preparing Your Saw for Use

Now install the new power cord in the

contactor box. Connect the ground wire

(the green wire) to the ground, the white

wire to the right, top terminal connection

on the contactor, and the black wire to

the left, top terminal connection on the

contactor (see Fig. 45). A wiring diagram

is shown in Fig. 46.

Using a Phillips screwdriver, remove the

left screw that attaches the bar across

the cords entering the contactor box and

loosen the right screw. Then rotate the

bar downwards far enough to remove

the power cord (see Fig. 44).

contactor

thermal

circuit

breaker

power

cable

ground

power cord

Green

Green

White

White

T1

T2

L1

L2

A2

COIL

THERMAL CIRCUIT

BREAKER

MOTOR

CABLE

POWER

CABLE

CONTACTOR BOX

SWITCH BOX

CABLE

A1

COIL

CONTACTOR

White

Black

Black

Red

Black

GROUND

230V Contactor Box Wiring Diagram:

Fig. 44

Fig. 45

Fig. 46

Advertising