Preparing Your Saw for Use

Disconnect the power cord from the contactor box by using a Phillips screwdriver to loosen the two screws at

the top of the contactor and removing the ends of the black and white power cord wires from the screws and

then removing the end of the green power cord wire from the ground connection (see Fig. 42 and 43).

With the saw unplugged, use a Phillips screwdriver to remove the four screws on the cover of the contactor

box and remove the contactor box cover (see Fig. 41). Locate the contactor to which the black and white wires

from the power cord are attached and the ground connection to which the green wire from the power cord is

attached (see Fig. 42).

contactor

ground

power cord

remove

contactor box

cover

Fig. 41

Fig. 42

Fig. 43