Distance Tables

The following tables provide the maximum distances for remote
power via Cat5 twisted pair when a port on the Passive CCTV/GLI
Hub is set to Pass-Thru Mode (500022) or Power-Thru Mode
(500024/500029).

Pass-Thru Mode (500022) – Two (2) Twisted Pairs

Voltage

Pcam

(W)

Vcam

1

min (V)

Dist Spec

2

max (Feet)

Dist Spec

2

max (m)

5

10.80

86

28

10

10.80

43

14

12 VDC/AC PSU
12VDC/AC camera

20

10.80

22

7

5

21.60

346

113

10

21.60

173

57

24 VAC PSU
24VAC camera

20

21.60

86

28

5

21.60

922

302

10

21.60

461

151

28 VAC PSU
24VAC camera

20

21.60

230

76

Power-Thru Mode (500024/500029) – Three Twisted
Pairs

Voltage

Pcam

(W)

Vcam

1

min (V)

Dist Spec

2

max (Feet)

Dist Spec

2

max (m)

5

10.80

130

43

12 VDC/AC PSU
12VDC/AC camera

10

10.80

65

21

5

21.60

518

170

10

21.60

259

85

24 VAC PSU
24VAC camera

20

21.60

130

43

5

21.60

1382

454

10

21.60

691

227

28 VAC PSU
24VAC camera

20

21.60

346

113

Notes:
1.

Distances are specified for temperatures of 20

o

C to 30

o

C

2.

Maximum distances based on 10% loss of voltage. For 28VAC, a 24VAC camera was

used.

3.

Distances specified are 90% of distances calculated.

4.

If 22AWG gage wire is used, there would be an increase in distance of approximately 56%.