Installation procedure – Muxlab Passive CCTV/GLI Hub User Manual

Page 9

Advertising
background image

© MuxLab Inc.

Passive CCTV/GLI Hub Installation Guide

Page 9

3.5.

Installation Procedure

The Passive CCTV/GLI Hub features BNC connectors
on the video portion of the device, thereby allowing it to
be connected directly to the DVR via coaxial cable. In
order to install the product in this configuration, please
follow the steps below:

1. Install the Passive CCTV/GLI Hub in its final

location. Please verify that the distance between the
rack and cameras are within MuxLab specifications.

2. Connect a MuxLab passive CCTV/GLI Balun

(MuxLab p/n 500000, 500009, 500022, 500023,
500024 or 500029) to each CCTV camera video
output. Please refer to the appropriate CCTV balun
installation guide for details.

3. Connect one Cat5 cable from each camera to one of

the modular RJ45 ports on the front of the Passive
CCTV/GLI Hub (fig 5). Please ensure that EIA 568
wiring and straight-through polarity is respected
between the CCTV balun and the rack. The use of
other Cat5 connection hardware such as patch panels
and 110 blocks is supported.

Figure 4: Camera connection

Advertising