Page 5

Mechanical & Environmental

Cable – UTP

24 AWG or lower solid copper twisted pair wire impedance: 100
ohms at 1 MHz
Maximum capacitance: 20 pf/foot. Attenuation: 6.6 dB/1000 ft at 1
MHz

Cable – Coax

Impedance: 75 O at 1 MHz. (RG59/U). Max. 25 ft. of coax allowed
end to end.

Connectors

Video (Model 500130): Sixteen (16) BNC-F
Video (Model 500131): Sixteen (16) 2-pole screw terminals
Power: Sixteen (16) 2-pole screw terminals
Control: Sixteen (16) 2-pole screw terminals.
Combined signals: Sixteen (16) RJ45 jacks

Port Configuration
Switch

Sets each port to Pass-Thru Mode (500022) or Power-Thru Mode
(500024/500029)

RJ45 Pin
Configuration*

Signal

500022 Mode

500024/500029
Mode

Power A (+)

1, 3

1, 3, 5

*Reverse polarity
sensitive

Power B (-)

2, 6

2, 4, 6

Control (+)

4

Not used

Control (-)

5

Not used

Video BNC Center (Tip) 7 [T] same as

500000R

7 [T] same as
500000R

Video BNC Ground
(Ring)

8 [R] same as
500000R

8 [R] same as
500000R

Temperature

Operating: 0° to 55°C. Storage:-20° to 85°C. Humidity: up to 95%

Enclosure

Black, anodized aluminum

Dimensions

19” (48.26 cm) W x 1.75” (4.4 cm) H x 2.0” ( 5.1 cm) D

Weight

2.3 lbs. (1.1kgs)

Warranty

Lifetime

Order
Information

500133 Passive CCTV Hub, UTP/Coax