RB-6 - Connecting the RB-6

15

15

Figure 9: Crossed Cable RS-232 Connection

Hardware flow control is not required for this unit. In the rare case where a

controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on

the controller side.

Method B (

Figure 10

)

—Connect the RS-232 9-pin D-sub port on the unit via a

straight (flat) cable to the null-modem adapter, and connect the null-modem

adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually

contains all nine wires for a full connection of the D-sub connector. Because the

null-modem adapter (which already includes the flow control jumpering described

in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to

decide whether to connect only these 3 pins or all 9 pins.

Figure 10: Straight Cable RS-232 Connection with a Null Modem Adapter

6.4

Connecting a PC or Controller to the RS-485 Port

You can operate the RB-6 via the RS-485 port from a distance of up to 1200m

(3900ft) using any device equipped with an RS-485 port (for example, a PC). For

successful communication, you must set the RS-485 machine number and bus

termination.

The first and last device on the RS-485 bus must be terminated. All other devices

must remain unterminated. Move the switch up to terminate and down to

unterminate.

Note: You cannot perform a firmware upgrade using the RS-485 port.

1

2

6

3

7

4

8

5

9

1

2

6

3

7

4

8

5

9

PC

1

2

6

3

7

4

8

5

9

to PC

Null-Modem

Adapter