12.1.2.1 Device Long Response

Echoing command:

Start

Address (optional)

Body

Delimiter

~

Sender_id@

Command SP [Param1 ,P

aram2 …] result

CR LF

CR = Carriage return (ASCII 13 = 0x0D)

LF = Line feed (ASCII 10 = 0x0A)

SP = Space (ASCII 32 = 0x20)

12.1.3

Command Terms

Command

A sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-').

Command and parameters must be separated by at least one space.

Parameters

A sequence of alphameric ASCII characters ('0'-'9','A'-'Z','a'-'z' and some special

characters for specific commands). Parameters are separated by commas.

Message string

Every command entered as part of a message string begins with a message

starting character and ends with a message closing character.

Note: A string can contain more than one command. Commands are separated by

a pipe ( '|' ) character.

Message starting character

'#'

– For host command/query

'~'

– For machine response or machine command performed by keystrOKe

operation on the front panel or IR remote controller.

Device address (Optional when directly connected to the device)

K-Net Device ID or MACHINE NUMBER followed by '@'

(ex. #02@ CRLF )

Query sign

'?' follows some commands to define a query request.