7 command chaining, 8 maximum string length, 9 backward support – Kramer Electronics RB-6 User Manual

Page 35: 2 supported commands, Supported commands

Advertising
background image

RB-6 - RB-6 Communication Protocol

31

31

12.1.7

Command Chaining

Multiple commands can be chained in the same string. Each command is

delimited by a pipe character ( '|' ). When chaining commands, enter the message

starting character and the message closing character only once, at the

beginning of the string and at the end.

Commands in the string do not execute until the closing character is entered.

A separate response is sent for every command in the chain.

12.1.8

Maximum String Length

64 characters

12.1.9

Backward Support

Protocol 2000 is transparently supported by Protocol 3000. You can switch

between protocols using a switch protocol command from either platform.

12.2

Supported Commands

For details regarding the commands, see the Kramer Protocol 3000 document.

The latest version of the document is available from

http://www.kramerelectronics.com

.

The following commands are supported by the RB-6.

Command

Description

Permission

#

Protocol handshaking

End User

BUILD-DATE?

Read device build date

End User

DIM_RANGE

Set the dimmer range

DIM_RANGE?

Read the dimmer range

DIM-VALUE

Set the dimmer value

DIM-VALUE?

Read the dimmer value

ETH-PORT

Change protocol Ethernet port

Administrator

ETH-PORT?

Get protocol Ethernet port

End User

FACTORY

Reset to factory default configuration

HELP

List of commands

End User

LDFW

Load new firmware

User SW Internal

MODEL?

Read device model

End User

NAME

Set machine (DNS) name

Administrator

NAME?

Get machine (DNS) name

End User

NAME-RST

Reset machine name to factory default (DNS)

Administrator

NET-DHCP

Set DHCP mode

Administrator

Advertising