CONFIDENTIAL

Unknown Procedure

Received procedure code is not defined

TMA Minor Fault

A fault in the TMA subunit is detected which reduces the gain

performance but maintains its function.

[SU 1]: SubUnit1 (Main Path) [YRMIN]

[SU 2]: SubUnit2 (Diversity Path)

TMA Major Fault

LNA alarm, TDD S/W alarm

[SU 1]: SubUnit1 (Main Path)

[SU 2]: SubUnit2 (Diversity Path)

Unsupported Value

The requested value is not supported.

Read Only

Invalid device data parameter usage

Unknown Parameter

Specified parameter is not supported for the used procedure

Bypass Mode

The TMA subunit is in bypass mode and cannot report a correct

gain value.

[SU 1]: SubUnit1 (Main Path)

[SU 2]: SubUnit2 (Diversity Path)

Working S/W Missing

The unit is in Download Mode state. Returned upon unsupported

procedure when in Download Mode state

Invalid File Content

The data being downloaded is detected to be of wrong format or

size

Format Error

Procedure message is inconsistent or if an addressed field or

antenna is invalid or the data parameter field length is

inconsistent with the corresponding field length parameter

Unsupported

Procedure

The procedure is optional and not supported or the procedure

does not apply to this device type

Invalid

Procedure

Sequence

Procedure sequence as described in annex C is expected but

not experienced by the secondary device

Actuator Interference

An actuator movement outside the control of the RET unit has

been detected. Probable cause is manual interference

) TICU information

Displays TICU information

Table

– TICU Information

ITEM

Description

Remark

ID

TICU ID

1 ~ 65535