) Connect

Change ALD status to Connect. When Disconnect, data is not sent and received. When command is

sent more than three times in Disconnect, ”Link Alarm” will be changed into red. (Use Refresh button to

check). In case that Link Alarm and Connect LED are in the state of green, it is possible to send a

command to ALD.

) Disconnect

Refer to 3) Connect.

) Refresh

Get the information of ALD and antenna stored on TICU.

) Get Subunits No.

Get the number of Subunits of TMA(refer to AISG v2.0). After checking the number of subunits, it is

possible to check the status of TMA Alarm individually.

) Reset(Layer 7)

Layer 7 Reset(status does not change after Reset).

) Alarm Subscribe

To monitor the status of alarm automatically, Alarm Subscribe command must be excuted.

) Get Alarm Status

Get ErrorCodes for ALD and antenna (refer to Table

– AISG_ERROR_CODE ).

) TMA Get Alarm