Ald control method (refer to aisg v2.0), Procedure (refer to aisg v2.0 document), Set assign – KMW Communications AMS Lite User Manual

Page 22: Confidential

Advertising
background image

Sheet 22 of 30

Sheet 22 of 30 8/17/2008

©

CONFIDENTIAL

. ALD Control Method (Refer to AISG v2.0)

Figure 8-1 shows the ALD

’s operation information and current status.

If you choose an ALD from the connected list, all information about the selected ALD will be displayed. And

each button executes the command compliant to AISG 2.0.

<Figure 8-1>

) Procedure (Refer to AISG v2.0 document)

 Choose the ALD from the

“Connected List”, and click “Connect” and “Refresh” button.

 In case of Green LED on

“Link alarm” and “Connect” LED, you can get information using

“Get” button.

 RET: There is no alarm, you can control the antenna

’s tilt degree using “Set Tilt” button. When

the Tilt operation is completed, get the current degree using

“Get Tilt” button.

 TMA: There are commands about TMA,

“Set TMA Mode”, “Get TMA Mode”, “Set TMA Gain”,

“Get TMA Gain” and “Get Supported Func”.

) Set Assign

When “Set Assign” (Figure 8-1) button is clicked, window will be displayed (Figure 8-2). This window

sets ID of ALD. ID for each ALD must be entered in order to control and monitor ALDs connected to

TICU.

The communication between TICU and ALD uses the ALD ID, so you must input the unused ID.

If same ID exists on the data bus, the other ALD makes it

’s own ID to NULL. The ID range is from 1 to

254. If the ALD is assigned to new ID, the ALD will be disconnected status.

Advertising