Confidential – KMW Communications AMS Lite User Manual

Page 17

Advertising
background image

Sheet 17 of 30

Sheet 17 of 30 8/17/2008

©

CONFIDENTIAL

executed successfully.

AISG_RET_CODE_NOT_CALIBRA

TED

0EH

The device has not completed a calibration operation, or calibration

has been lost.

AISG_RET_CODE_NOT_CONFIG

URED

0FH

Actuator configuration data is missing.

AISG_RET_CODE_HARDWARE_E

RROR

11H

Any hardware error which cannot be classified. May not be reported

as an alarm until the fault is likely to be persistent.

AISG_RET_CODE_OUT_OF_RAN

GE

13H

A parameter given by an operator (e.g. tilt value or memory offset) is

out of range.

AISG_RET_CODE_UNKNOWN_P

ROCEDURE

19H

Received procedure code is not defined.

AISG_RET_CODE_MINOR_TMA_F

AULT

1AH

A fault in the TMA subunit is detected which reduces the gain

performance but maintains its function.

AISG_RET_CODE_MAJOR_TMA_

FAULT

1BH

A fault in the TMA subunit is detected. The fault prevents the function

of the TMA subunit.

AISG_RET_CODE_UNSUPPORTE

D_VALUE

1CH

The requested value is not supported.

AISG_RET_CODE_READ_ONLY

1DH

Invalid device data parameter usage.

AISG_RET_CODE_UNKNOWN_PA

RAMETER

1EH

Specified parameter is not supported for the used procedure.

AISG_RET_CODE_BYPASS_MOD

E

1FH

The TMA subunit is in bypass mode and cannot report a correct gain

value.

AISG_RET_CODE_WORKING_SO

FTWARE_MISSING

21H

The unit is in DownloadMode state. Returned upon unsupported

procedure when in DownloadMode state.

AISG_RET_CODE_INVALID_FILE_

CONTENT

22H

The data being downloaded is detected to be of wrong format or

size.

AISG_RET_CODE_FORMAT_ERR

OR

24H

Procedure message is inconsistent or if an addressed field or

antenna is invalid or the data parameter field length is inconsistent

with the corresponding field length parameter.

AISG_RET_CODE_UNSUPPORTE

D_PROCEDURE

25H

The procedure is optional and not supported or the procedure does

not apply to this device type.

AISG_RET_CODE_INVALID_PRO

CEDURE_SEQUENCE

26H

Procedure sequence as described in annex C is expected but not

experienced by the secondary device.

AISG_RET_CODE_ACTUATOR_IN

TERFERENCE

27H

An actuator movement outside the control of the RET unit has been

detected. Probable cause is manual interference.