Installing or removing the intrusion switch – Lenovo ThinkServer RD550 User Manual

Page 116

Advertising
background image

8. Tighten the two screws to secure the AnyRAID adapter or the pass-through board.

Figure 70. Tightening the screws

9. If you are instructed to return the old AnyRAID adapter or the pass-through board, follow all packaging

instructions and use any packaging materials that are supplied to you for shipping.

What to do next:

• To work with another piece of hardware, go to the appropriate section.

• To complete the replacement, go to “Completing the parts replacement” on page 144.

Installing or removing the intrusion switch

The intrusion switch informs you that the server cover is not properly installed or closed by creating an event
in the system event log (SEL). You can purchase an intrusion switch from Lenovo.

Installing the intrusion switch

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 61.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

Note: Use any documentation that comes with the intrusion switch and follow those instructions in addition
to the instructions in this topic.

102

ThinkServer RD550 User Guide and Hardware Maintenance Manual