Lenovo ThinkServer RD550 User Manual

Page 117

Advertising
background image

To install the intrusion switch, do the following:

1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all

power cords from electrical outlets and disconnect all cables that are connected to the server.

2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 63.

3. Remove the server cover. See “Removing the server cover” on page 63.

4. Touch the static-protective package that contains the intrusion switch to any unpainted surface on the

outside of the server. Then, take the intrusion switch out of the package.

5. Press the tab

1

outward as shown and then lower the intrusion switch until it is secured in the socket.

Figure 71. Installing the intrusion switch

6. Connect the intrusion switch cable to the intrusion switch connector on the system board. See “System

board components” on page 37.

What to do next:

• To work with another piece of hardware, go to the appropriate section.

• To complete the installation, go to “Completing the parts replacement” on page 144.

Removing the intrusion switch

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 61.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.