OUTPut:RELay

Agilent 66332A, 6632B, 6633B, 6634B, 6611C, 6612C, 6613C, 6614C Only

This command is only valid for units with Relay Option 760, otherwise an error will occur. Programming
ON closes the output relay contacts; programming OFF opens them. The relay is controlled independently
of the output state. If the dc source is supplying power to a load, that power will appear at the relay
contacts during switching.

Command Syntax

OUTPut:RELay[:STATe]<bool>

Parameters

0 | 1 | OFF ON

*RST Value

0

Examples

OUTP:REL 1OUTP:REL OFF

Query Syntax

OUTPput:RELay?

Returned Parameters

0 | 1

Related Commands

OUTP *RCL *SAV

OUTPut:RELay:POLarity

Agilent 66332A, 6632B, 6633B, 6634B, 6611C, 6612C, 6613C, 6614C Only

This command is only valid for units with Relay Option 760, otherwise an error will occur. Programming
NORMal causes the output relay polarity to be the same as the dc source output. Programming REVerse
causes the relay output polarity to be opposite to that of the dc source output. If OUTPut = ON when either
command is sent, the output voltage is set to 0 during the time that the relays are changing polarity.

Command Syntax

OUTPut:RELay:POLarity<CRD>

Parameters

NORMal | REVerse

*RST Value

NORM

Examples

OUTP:REL:POL NORM

Query Syntax

OUTPput:RELay:POLarity?

Returned Parameters

NORM | REV

Related Commands

OUTP *RCL *SAV

OUTPut:RI:MODE

This command selects the mode of operation of the Remote Inhibit protection. The RI mode is stored in
non-volatile memory. The following modes can be selected:

LATChing

causes a TTL low signal on the INH input to disable the output. The only way
to clear the latch is by sending an OUTPut:PROTection:CLEAR command
while the INH input is false.

LIVE

allows the INH input to disable the output in a non-latching manner. In other
words, the output follows the state of the INH input. When INH is low true, the
output is disabled. When INH is high the output is not affected.

OFF

the INH input is disabled.

Command Syntax

OUTPut:RI:MODE <mode>

Parameters

LATChing | LIVE | OFF

Examples

OUTP:RI:MODE LIVE

Query Syntax

OUTPut:RI:MODE?

Returned Parameters

<CRD>