Programming the status registers, Power-on conditions, 3 - programming the dc source 32 – Agilent Technologies 6631B User Manual

Page 32

Advertising
background image

3 - Programming the DC Source

32

Programming the Status Registers

You can use status register programming to determine the operating condition of the dc source at any
time. For example, you may program the dc source to generate an interrupt (assert SRQ) when an event
such as a current limit occurs. When the interrupt occurs, your program can then act on the event in the
appropriate fashion.

Figure 3-7 shows the status register structure of the dc source. Table 3-1 defines the status bits. The
Standard Event, Status Byte, and Service Request Enable registers and the Output Queue perform
standard GPIB functions as defined in the

IEEE 488.2 Standard Digital Interface for Programmable

Instrumentation. The Operation Status and Questionable Status registers implement functions that are
specific to the dc source.

Power-On Conditions

Refer to the *RST command description in chapter 4 for the power-on conditions of the status registers.

Figure 3-7. DC Source Status Model

8

16

32

64

128

L

OGI

C

A

L

O

R

STATUS BYTE

3

4

5

6

7

N.U.

QUES

MAV

ESB

MSS

OPER

SERVICE

REQUEST

GENERATION

RQS

8

16

32

128

REQUEST

ENABLE

SERVICE

1

2

16

512

1024

CONDITION

1

2

16

512

1024

EVENT

1

2

16

512

1024

ENABLE

1

2

16

512

1024

PTR/NTR

L

OGI

C

A

L

OR

0

1

2

4

5-8

9

10

11-13

OV

OCP

FS

OT

N.U.

RI

Unreg

N.U.

QUESTIONABLE STATUS

1

4

8

16

32

128

1

4

8

16

32

128

L

O

GI

CA

L

OR

OPC

N.U.

QYE

DDE

EXE

CME

N.U.

PON

EVENT

ENABLE

STANDARD EVENT STATUS

DATA

DATA

DATA

OUTPUT QUEUE

QUEUE

NOT

EMPTY

1

CONDITION

1

EVENT

1

ENABLE

1

32

256

1024

2048

PTR/NTR

L

OGI

C

A

L

OR

0

1-4

5

6,7

8

9

10

11

12-15

OPERATION STATUS

512

CAL

N.U.

WTG

N.U.

CV

N.U.

CC+

CC-

N.U.

32

256

1024

2048

512

32

256

1024

2048

512

32

256

1024

2048

512

0

1

2

3

4

5

6

7

0-2

FLT

),**$/

N.U.

3

4

4

4

4

16384

16384

16384

16384

MeasOvld

14

N.U.

15

OFF

OU

T

P

u

t:D

FI

:SOU

R

c

e

Advertising