Fig. 11—wiring diagram – Bryant 395CAV User Manual

Page 12

Advertising
background image

Fig. 11—Wiring Diagram

A00198

PCB

BLOWER OFF DELAY

SELECTION CHART

90 SEC

135 SEC

180 SEC

225 SEC

GVR

HI/LO

RELAY

SEC-1

SEC-2

PL1

3 2 1

6 5 4
9 8 7

LED

TEST/TWIN

BLOWER

OFF

DELAY

G
R
Y

W
C

HUM

HSIR

IDR

BLWR

BLOWER

SPEED

SELECT

FU1

COOL

HEAT

L2

PL3

PL2

VAC

120

L1

PR1

1

2

1
2
3

PR2

24 VAC-3A

FUSE

SPARE-2

SPARE-1

EAC-1

EAC-2

C

1.

5

A

M

P

1

2

PL5

WHT

BLK

WHT

WHT

BL

K

BL

K

HSI

BLK

WHT

WHT (COM)

RED (LO)

BLU (MED LO)

NOTE #7

OL

START

BLWM

YEL (MED HI)

BLK (HI)

BRN

BRN

TR

A

N

BLU

RED

BLK

WHT

WHT (COM)

CAP

RED

RED

ORN

FUSED DISCONNECT

SWITCH (WHEN REQ'D)

NOTE #4

FU2

BLK

WHT

JB

LEGEND

ALS

AUXILIARY LIMIT SWITCH, OVERTEMP. -MANUAL RESET, SPST-(N.C.)

BLWR

BLOWER MOTOR RELAY, SPST-(N.O.)

BLWM BLOWER MOTOR
BVSS

BLOCKED VENT SHUTOFF SWITCH, SPST - (N.C.)

CAP

CAPACITOR

CPU

MICROPROCESSOR AND CIRCUITRY

DSS

DRAFT SAFEGUARD SWITCH

EAC-1

ELECTRONIC AIR CLEANER CONNECTION (115 VAC 1.5 AMP MAX.)

EAC-2

ELECTRONIC AIR CLEANER CONNECTION (COMMON)

FL

FUSIBLE LINK

FRS

FLAME ROLLOUT SW. -MANUAL RESET, SPST- (N.C.)

FSE

FLAME PROVING ELECTRODE

FU1

FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED

FU2

FUSE OR CIRCUIT BREAKER CURRENT INTERRUPT DEVICE
(FIELD INSTALLED & SUPPLIED)

GV

GAS VALVE-REDUNDANT OPERATORS

GVR

GAS VALVE RELAY, DPST- (N.O.)

HI/LO

BLOWER MOTOR SPEED CHANGE RELAY, SPDT

HSI

HOT SURFACE IGNITOR (115 VAC)

HSIR

HOT SURFACE IGNITOR RELAY, SPST- (N.O.)

HUM

24VAC HUMIDIFIER CONNECTION (.5 AMP. MAX.)

IDM

INDUCED DRAFT MOTOR

IDR

INDUCED DRAFT RELAY, SPST- (N.O.)

ILK

BLOWER ACCESS PANEL INTERLOCK SWITCH, SPST- (N.O.)

JB

JUNCTION BOX

LED

LIGHT-EMITTING DIODE FOR STATUS CODES

LGPS

LOW GAS PRESSURE SWITCH, SPST-(N.O.)

LS

LIMIT SWITCH, AUTO RESET, SPST(N.C.)

OL

AUTO-RESET INTERNAL MOTOR OVERLOAD TEMP. SW.

PCB

PRINTED CIRCUIT BOARD

PL1

9-CIRCUIT CONNECTOR

PL2

2-CIRCUIT PCB CONNECTOR

PL3

3-CIRCUIT IDM CONNECTOR

PL5

2-CIRCUIT HSI/PCB CONNECTOR

PRS

PRESSURE SWITCH, SPST-(N.O.)

TEST/TWIN

COMPONENT TEST & TWIN TERMINAL

TRAN

TRANSFORMER-115VAC/24VAC

JUNCTION

UNMARKED TERMINAL

PCB TERMINAL

FACTORY WIRING (115VAC)

FACTORY WIRING (24VAC)

FIELD WIRING (115VAC)

FIELD WIRING (24VAC)

CONDUCTOR ON PCB

FIELD WIRING TERMINAL

FIELD GROUND

EQUIPMENT GROUND

FIELD SPLICE

PLUG RECEPTACLE

L1

L2

L1

BLWR

HI/LO

TO 115VAC FIELD DISCONNECT

NOTE #4

EQUIPMENT GROUND

SPARE-2

HEAT

SPARE-1

COOL

NOTE #7

COM

HSIR

EAC-1

START

OL

COM

HI

MED HI

MED LO

LO

BLWM

SCHEMATIC DIAGRAM

(NATURAL GAS & PROPANE)

EAC-2

1

1

HSI

2

PL5

2

PL2

3 PL3

PR2

115VAC

PR1

TRAN

24VAC

1

2

IDR

TEST/TWIN

FU1

NOTE #6

CAP

L2

PL1

8

FSE

9

6

5

CPU

HSIR

IDR

BLWR

Y

G

C

R

W

GVR-2

SEC-1

HI/LO

GVR

SEC-2

NOTES:

322869-101 REV. H

1. If any of the original equipment wire is replaced use wire rated for 105

C.

2. Inducer (IDM) and blower (BLWM) motors contain internal auto-reset thermal overload switches (OL).
3. Blower motor speed selections are for average conditions, see installation instructions for details on

optimum speed selection.

4. Use only copper wire between the disconnect switch and the furnace junction box (JB).
5. This wire must be connected to furnace sheetmetal for control to detect flame.
6. Replace only with a 3 amp fuse.
7. Yellow lead not on all motors.
8. Blower-on delay, gas heating 45 seconds, cooling or heat pump 2 seconds.
9. Blower-off delay, gas heating 90, 135, 180 or 225 seconds, cooling or heat pump 90 seconds.

(135 seconds only on some models)

10. Ignition-lockout will occur after four consecutive unsuccessful trials-for-ignition. Control will auto-reset

after three hours.

11. When used, auxiliary limit switch (ALS) is on some downflow models only. When used, FL is on

upflow models only.

12. Some models may have spade quick connect terminals.
13. Factory connected when LGPS is not used.
14. Factory connected when BVSS is not used. BVSS used when Chimney Adapter Accessory Kit is

installed.

15. Gas valve leads are interchangeable on single stage valves.

BL

K

OM

SW2

SW1

OM

3

4

7

1

OM

HUM

IDM

ILK

DSS

BVSS

PRS

ILK

L1

NEUTRAL

IDM

(WHEN USED)

NOTE #14

NOT USED

NOT USED

NOT USED

FSE

BLU

PRS

DSS

BVSS

(WHEN USED)

NOTE #14

WHT

LS

FL

(NOT ON ALL MODELS)

NOTE #9

FRS1

FRS2

LS

FL

NOTE #12

ORN

ORN

ORN

ALS

(WHEN USED)

ORN

NOTE #11

LGPS

(WHEN USED)

NOTE #13

NOTE #14

NOTE #11

2

GVR-1

NOTE #14

ALS

(WHEN USED)

(WHEN USED)

NOTE #13

LGPS

(WHEN USED)

NOTE #13

YEL

FRS1

FRS2

(WHEN USED) NOTE #11

GRN/YEL

GRN/YEL

GND

NOTE #5

GRN/YEL

NOTE #5

GRN/YEL

NOTE #15

NOTE #15

GV

GV


12