TABLE 6—MODEL 395CAV ORIFICE SIZE* AND MANIFOLD PRESSURE FOR CORRECT INPUT

(TABULATED DATA BASED ON 22,000 BTUH PER BURNER, DERATED 4 PERCENT FOR EACH 1000 FT ABOVE SEA LEVEL)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

0

to

2000

850

42

3.6

42

3.8

41

3.5

41

3.6

41

3.7

875

42

3.4

42

3.6

42

3.7

42

3.8

41

3.5

900

42

3.2

42

3.4

42

3.5

42

3.6

42

3.7

925

43

3.7

42

3.2

42

3.3

42

3.4

42

3.5

950

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

975

43

3.4

43

3.5

43

3.6

43

3.7

43

3.8

1000

43

3.2

43

3.3

43

3.4

43

3.5

43

3.6

1025

44

3.5

43

3.2

43

3.3

43

3.4

43

3.5

1050

44

3.3

44

3.4

44

3.6

43

3.2

43

3.3

1075

45

3.8

44

3.3

44

3.4

44

3.5

43

3.2

1100

45

3.7

45

3.8

44

3.2

44

3.4

44

3.5

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

U.S.A.

Altitudes

2001

to

3000

or

Canada

Altitudes

2000

to

4500

775

42

3.4

42

3.5

42

3.6

42

3.7

42

3.8

800

43

3.8

42

3.3

42

3.4

42

3.5

42

3.6

825

43

3.6

43

3.7

42

3.2

42

3.3

42

3.4

850

43

3.4

43

3.5

43

3.6

43

3.8

42

3.2

875

43

3.2

43

3.3

43

3.4

43

3.5

43

3.6

900

43

3.0

43

3.1

43

3.2

43

3.3

43

3.4

925

43

2.9

43

3.0

43

3.1

43

3.2

43

3.3

950

43

2.7

43

2.8

43

2.9

43

3.0

43

3.1

975

43

2.6

43

2.7

43

2.8

43

2.9

43

2.9

1000

43

2.5

43

2.5

43

2.6

43

2.7

43

2.8

1025

43

2.3

43

2.4

43

2.5

43

2.6

43

2.7

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

3001

to

4000

750

43

3.8

42

3.3

42

3.4

42

3.5

42

3.6

775

43

3.6

43

3.7

43

3.8

42

3.3

42

3.4

800

43

3.4

43

3.5

43

3.6

43

3.7

43

3.8

825

43

3.2

43

3.3

43

3.4

43

3.5

43

3.6

850

43

3.0

43

3.1

43

3.2

43

3.3

43

3.4

875

43

2.8

43

2.9

43

3.0

43

3.1

43

3.2

900

43

2.7

43

2.8

43

2.9

43

2.9

43

3.0

925

43

2.5

43

2.6

43

2.7

43

2.8

43

2.9

950

43

2.4

43

2.5

43

2.6

43

2.6

43

2.7

975

43

2.3

43

2.4

43

2.4

43

2.5

43

2.6

1000

43

2.2

43

2.2

43

2.3

43

2.4

43

2.5

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

4001

to

5000

725

43

3.6

43

3.7

42

3.2

42

3.3

42

3.4

750

43

3.4

43

3.5

43

3.6

43

3.7

43

3.8

775

43

3.2

43

3.3

43

3.4

43

3.5

43

3.6

800

43

3.0

43

3.1

43

3.2

43

3.3

43

3.4

825

43

2.8

43

2.9

43

3.0

43

3.1

43

3.2

850

43

2.6

43

2.7

43

2.8

43

2.9

43

3.0

875

43

2.5

43

2.6

43

2.6

43

2.7

43

2.8

900

43

2.3

43

2.4

43

2.5

43

2.6

43

2.7

925

43

2.2

43

2.3

43

2.4

43

2.4

43

2.5

950

43

2.1

43

2.2

43

2.2

43

2.3

43

2.4

* Orifice numbers shown in shading are factory installed