Bryant Condensing Gas 355CAV User Manual

Page 19

Advertising
background image

19

Table 1 – Opening Dimensions (in./mm)

FURNACE

CASING

WIDTH

APPLICATION

(APPROVED FACTORY SUPPLIED CASED COILS AND COIL BOX:

CD5, CKR, CAPVP, CARVP, CAPMP, CARMP, CNPVP, CNRVP, AND

KCAKC)

PLENUM OPENING

FLOOR OPENING

A

B

C

D

17

½ in.

445 mm

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

16 in./

406 mm

24--1/8 in./

613 mm

16--5/8 in./

422 mm

24--3/4 in./

629 mm

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

15--7/8 in./

403 mm

19 in./

483 mm

16--1/2 in./

419 mm

19--5/8 in./

498 mm

Downflow applications on combustible flooring

(KGASB sub-

base required)

15--1/8 in./

384 mm

19 in./

483 mm

16--3/4 in./

425 mm

20--3/8 in./

518 mm

Downflow Applications on Combustible Flooring with Factory

supplied cased coil or Factory supplied coil box (KGASB
subbase not required)

15--1/2 in./

394 mm

19 in./

483 mm

16--1/2 in./

419 mm

20 in./

508 mm

21 in./

533 mm

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

19--1/2 in./

495 mm

24--1/8 in./

613 mm

20--1/8 in./

511 mm

24--3/4 in./

629 mm

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

19--3/8 in./

492 mm

19 in./

483 mm

20 in./

508 mm

19--5/8 in./

498 mm

Downflow applications on combustible flooring

(KGASB sub-

base required)

18--5/8 in.

473 mm

19 in./

483 mm

20--1/4 in./

514 mm

20--3/8 in./

518 mm

Downflow Applications on Combustible Flooring with Factory

supplied cased coil or Factory supplied coil box (KGASB

subbase not required)

19 in./

483 mm

19 in./

483 mm

20 in./

508 mm

20 in./

508 mm

24--1/2 in./

622 mm

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

23 in./

584 mm

24--1/8 in./

613 mm

23--5/8 in./

600 mm

24--3/4 in./

629 mm

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

22--7/8 in./

581 mm

19 in./

483 mm

23--1/2 in./

597 mm

19--5/8 in.

498 mm

Downflow applications on Combustible flooring

(KGASB

subbase required)

22--1/8 in./

562 mm

19 in./

483 mm

23--3/4 in./

603 mm

20--3/8 in./

518 mm

Downflow Applications on Combustible Flooring with Factory

supplied cased coil or Factory supplied coil box (KGASB

subbase not required)

22--1/2 in./

572 mm

19 in./

483 mm

23--1/2 in./

597 mm

20 in./

508 mm

AIR DUCTS

General Requirements
The duct system should be designed and sized according to

accepted national standards such as those published by: Air
Conditioning Contractors Association (ACCA), Sheet Metal and

Air Conditioning Contractors National Association (SMACNA)

or American Society of Heating, Refrigerating and Air
Conditioning Engineers (ASHRAE) or consult The Air Systems

Design Guidelines reference tables available from your local
distributor. The duct system should be sized to handle the

required system design CFM at the design static pressure.
When a furnace is installed so that the supply ducts carry air
circulated by the furnace to areas outside the space containing the

furnace, the return air must also be handled by a duct(s) sealed to
the furnace casing and terminating outside the space containing

the furnace.
Secure ductwork with proper fasteners for type of ductwork used.

Seal supply-- and return--duct connections to furnace with code

approved tape or duct sealer.
Flexible connections should be used between ductwork and

furnace to prevent transmission of vibration. Ductwork passing
through unconditioned space should be insulated to enhance

system performance. When air conditioning is used, a vapor

barrier is recommended.
Maintain a 1--in. (25.4mm) clearance from combustible materials

to supply air ductwork for a distance of 36 in. (914.4mm)
horizontally from the furnace. See NFPA 90B or local code for

further requirements.
For a furnace not equipped with a cooling coil, the outlet duct
shall be provided with a removable access panel. This opening

shall be accessible when the furnace is installed and shall be of
such a size that the heat exchanger can be viewed for possible

openings using light assistance or a probe can be inserted for
sampling the air stream. The cover attachment shall prevent leaks.

Ductwork Acoustical Treatment
Metal duct systems that do not have a 90 degree elbow and 10 ft

(3 m) of main duct to the first branch take--off may require
internal acoustical lining. As an alternative, fibrous ductwork may

be used if constructed and installed in accordance with the latest
edition of SMACNA construction standard on fibrous glass

ducts. Both acoustical lining and fibrous ductwork shall comply

with NFPA 90B as tested by UL Standard 181 for Class 1 Rigid
air ducts.
Supply Air Connections
Upflow Furnaces
Connect supply--air duct to 3/4--in. (19.0mm)flange on furnace

supply--air outlet. The supply--air duct attachment must ONLY be

connected to furnace supply--/outlet--air duct flanges or air
conditioning coil casing (when used). DO NOT cut main furnace

casing to attach supply side air duct, humidifier, or other
accessories. All accessories MUST be connected external to

furnace main casing.
Downflow Furnaces
Connect supply--air duct to supply--air opening on furnace. The
supply--air duct attachment must ONLY be connected to furnace

supply/outlet or air conditioning coil casing (when used) when

installed on non--combustible material

When installed on

combustible material, supply air duct attachment must ONLY be

connected to an accessory subbase or factory approved air
conditioning coil casing. DO NOT cut main furnace casing to

attach supply side air duct, humidifier, or other accessories. All

accessories MUST be connected external to furnace main casing.
Supply air opening duct flanges must be modified per Fig. 22.
Horizontal Furnaces
Connect supply--air duct to supply--air opening on furnace. The

supply--air duct attachment must ONLY be connected to furnace
supply/outlet or air conditioning coil casing (when used). DO

NOT cut main furnace casing to attach supply side air duct,

355C

A

V