Warning, 355c a v – Bryant Condensing Gas 355CAV User Manual

Page 8

Advertising
background image

8

1/2 OD
INDUCER HOUSING
DRAIN CONNECTION

1/4 OD
COLLECTOR BOX TO
TRAP RELIEF PORT

5/8 OD
COLLECTOR BOX
DRAIN CONNECTION

1/2 IN. PVC OR CPVC

SCREW HOLE FOR
UPFLOW OR DOWN-
FLOW APPLICATIONS
(OPTIONAL)

1 4

2

7 8

1 8

7

SLOT FOR SCREW

HORIZONTAL

APPLICATION

(OPTIONAL)

WIRE TIE
GUIDES
(WHEN USED)

1 2

1

3 4

1

3 4

FRONT VIEW

SIDE VIEW

FURNACE
DOOR

FURNACE
DOOR

CONDENSATE
TRAP

78

1 4

26

4

FURNACE
SIDE

FURNACE

SIDE

1 2

1

1 4

26

4

3 4

5

3 4

5

4

SIDE VIEW

FRONT VIEW

END VIEW

FRONT VIEW

3 4

DOWNFLOW AND ALTERNATE

EXTERNAL UPFLOW APPLICATIONS

HORIZONTAL

APPLICATIONS

FIELD

DRAIN

CONN

FIELD

DRAIN

CONN

CONDENSATE
TRAP (INSIDE)

BLOWER SHELF

ALTERNATE DRAIN
TUBE LOCATION

UPFLOW APPLICATIONS

CONDENSATE TRAP

DRAIN TUBE LOCATION

(667mm)

(38mm)

(124mm)

(667mm)

(19mm)

(146mm)

(146mm)

(57mm)

(3mm)

(181mm)

(44mm)

(88mm)

(19mm)

A07459

Fig. 6 -- Condensate Trap

NOTE: Failure to use CPVC elbows may allow drain to kink,
preventing draining.

k. Connect larger diameter drain tube and clamp

(factory--supplied in loose parts bag) to condensate trap
and clamp securely.

l. Route tube to coupling and cut to appropriate length.

m. Attach tube to coupling and clamp securely.

Condensate Trap (Alternate Upflow Orientation)
An alternate location for the condensate trap is the left--hand side
of casing. (See Fig. 2 and 8.)
NOTE: If the alternate left--hand side of casing location is used,
the factory--connected drain and relief port tubes must be
disconnected and modified for attachment. See Condensate Trap
Tubing (Alternate Upflow Orientation) section for tubing
attachment.
To relocate condensate trap to the left--hand side, perform the
following:

1. Remove three tubes connected to condensate trap.
2. Remove trap from blower shelf by gently pushing tabs

inward and rotating trap.

3. Install casing hole filler cap (factory--supplied in loose

parts bag) into blower shelf hole where trap was removed.

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal

injury or death.
Casing hole filler cap must be installed in blower shelf

hole when condensate trap is relocated to prevent

combustion products being drawn in from appliances in

the equipment room.

!

WARNING

4. Install condensate trap into left--hand casing hole by

inserting tube connection stubs through casing hole and

rotating until tabs snap into locking position.

5. Fill unused condensate trap casing holes with plastic filler

caps (factory--supplied in loose parts bag).

Condensate Trap Tubing (Alternate Upflow Orientation)
NOTE
: See Fig. 8 or tube routing label on main furnace door to
confirm location of these tubes.

355C

A

V

Advertising