Bryant Condensing Gas 355CAV User Manual

Page 9

Advertising
background image

9

PLUG

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE &

WHITE STRIPED)

INDUCER HOUSING

(MOLDED) DRAIN

TUBE (BEHIND

COLLECTOR BOX

DRAIN TUBE)

COLLECTOR BOX

TUBE (PINK)

COLLECTOR BOX

DRAIN TUBE (BLUE)

COLLECTOR BOX

TUBE (GREEN

ROUTES BEHIND

INDUCER)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (LEFT

DRAIN OPTION)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

FIELD-INSTALLED

FACTORY-SUPPLIED

½ - IN. CPVC STREET

ELBOWS (2) FOR

LEFT DRAIN OPTION

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (LEFT

DRAIN OPTION)

CONDENSATE

TRAP

A07274

Fig. 7 -- Factory--Shipped Trap Location

(Shown with Blower Access Panel Removed)

1. Collector Box Drain Tube

Connect collector box drain tube (blue label) to

condensate trap.

NOTE: On 17--1/2--in. (444.5mm) wide furnaces ONLY, cut
tube between corrugated sections to prevent kinks.

2. Inducer Housing Drain Tube

a. Remove and discard LOWER (molded) inducer housing

drain tube which was previously connected to condensate
trap.

b. Use inducer housing drain extension tube (violet label

and factory--supplied in loose parts bag) to connect
LOWER inducer housing drain connection to

condensate trap.

c. Determine appropriate length, then cut and connect tube.

d. Clamp tube to prevent any condensate leakage.

3. Relief Port Tube

a. Connect relief port tube (green label) to condensate trap.

b. Extend this tube (if required) by splicing to small

diameter tube (factory--supplied in loose parts bag).

c. Determine appropriate length, then cut and connect tube.

Condensate Trap Field Drain Attachment
Refer to Condensate Drain section for recommendations and

procedures.

PLUG

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE &

WHITE STRIPED)

INDUCER HOUSING

(MOLDED) DRAIN

TUBE (VIOLET)

COLLECTOR BOX

TUBE (PINK)

COLLECTOR BOX

DRAIN TUBE (BLUE)

COLLECTOR BOX

TUBE (GREEN)

CONDENSATE

TRAP

A07281

Fig. 8 -- Alternate Trap Location

Pressure Switch Tubing
The LOWER collector box pressure tube (pink label) is factory
connected to the pressure switch and should not require any

modification.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace
door to check for proper connections.
Upper Collector Box and Inducer Housing (Unused) Drain
Connections
Upper Collector Box Drain Connection
Attached to the UPPER collector box drain connection is a

factory--installed corrugated,

plugged tube (blue and white

striped label). This tube is plugged to prevent condensate leakage

in this application. Ensure this tube is plugged.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace
door to check for proper connections.
Upper Inducer Housing Drain Connection
Attached to the UPPER (unused) inducer housing drain
connection is a cap and clamp. This cap is used to prevent

condensate leakage in this application. Ensure this connection is
capped.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace
door to check for proper connections.
Condensate Trap Freeze Protection
Refer

to

Condensate

Drain

Protection

section

for

recommendations and procedures.