Type "B" for 115.2K baud rate. The DS71
responds with the new configuration status:

Module 1 Serial Port Configuration :

Port

Device
Name

Baud
Rate

Word
Size

Stop
Bits

Parity

Xon/
Xmit

Xoff/
Recv

Line
DTR

Drive
RTS

1

EIA-232

115.2K

8

1

None

Off

Off

High

High

Exit/Save..….......1

Set Parity...….........5

Set Baud Rate….2

Set Xon/Xoff….......6

Set Word Size….3

RTS Line Driver....7

Set Stop Bits..…..4

DTR Line Driver...8

Enter Request :

Set Word Size by selecting #3, “Set Word
Size.” The DS71 displays the following list
of available word sizes:

1 For 5
2 For 6
3 For 7
4 For 8

Enter the corresponding number for the
desired word size. The DS71 responds with
the new configuration status:

Module 1 Serial Port Configuration :

Port

Device
Name

Baud
Rate

Word
Size

Stop
Bits

Parity

Xon/
Xmit

Xoff/
Recv

Line
DTR

Drive
RTS

1

EIA-232

115.2K

8

1

None

Off

Off

High

High

Exit/Save..….......1

Set Parity...….........5

Set Baud Rate….2

Set Xon/Xoff….......6

Set Word Size….3

RTS Line Driver....7

Set Stop Bits..…..4

DTR Line Driver...8

Enter Request :

To permanently save configuration changes,
select 1, “Exit/Save,” from the selection
menu, followed by <cr>. The DS71
responds:

Change Host Device to Match NEW Configuration
Before Answering this Request
Save Changes Permanently ? (Y/N) :