DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________

32

NOTE: DTR is unchangeable when configuring the serial port.
When configuring the Host Modem, Xon/Xoff, RTS, and DTR are
hardware settings and, therefore, unchangeable.

For example, to change the baud rate to
115.2K, select #2, “Set Baud Rate,” followed
by <cr>.

The DS71-MD2 displays the following list of
available baud rates:

1 for 300
2 for 600
3 for 1200
4 for 2400
5 for 4800
6 for 9600
7 for 19200
8 for 38400
9 for 57.6K
A for 76.8K
B for 115.2K
Enter Request :

Type "B" for 115.2K baud rate. The DS71-
MD2 responds with the new configuration
status:

Module 1 Serial Port Configuration :

Port

Device
Name

Baud
Rate

Word
Size

Stop
Bits

Parity

Xon/
Xmit

Xoff/
Recv

Line
DTR

Drive
RTS

2

Host MODEM

115.2K

8

1

None

Off

Off

High

High

Exit/Save..….......1

Set Parity...….........5

Set Baud Rate….2

Set Xon/Xoff….......6

Set Word Size….3

RTS Line Driver....7

Set Stop Bits..…..4

DTR Line Driver...8

Enter Request :