Connection from the 25-pin Admin Port to a Terminal

For a terminal operating at speeds faster than 9600 baud, or for a terminal which
cannot use xon/xoff flow control, the following connections are required:

Notes:

1. In addition to the signals shown in the examples above, you may connect

Protective Ground (P/GND) if you have shielded twisted-pair (STP) cable.
Connect P/GND at either your equipment or the Black Box device (but not both).
P/GND will reduce interference in noisy environments.

2. * asterisk denotes that you connect CTS to CTS only if input flow control (from

the Terminal to the Black Box device) is required.

B l a c k

B o x

2 5 - p i n

A d m i n

P o r t

T e r m i n a l

D B 2 5

D B 2 5

T X D

3

— — — — — — — >

3

R X D

R X D

2

< — — — — — — —

2

T X D

G N D

7

— — — — — — — —

7

G N D

B l a c k

B o x

d e v i c e

T e r m i n a l

R S 2 3 2

R J 4 5

D B 2 5

R X D

6

< — — — — — — — —

2

T X D

T X D

5

— — — — — - - — >

3

R X D

R T S

8

< — — — — — — — —

4

o r

2 0

R T S

o r

D T R

* C T S

7

— — — — — - - — >

5

* C T S

S / G N D

4

— — — — — — — -

7

S / G N D