Programming the brewer (cont.) – Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 25

Advertising
background image

Page 25

P2444

PROGRAMMING THE BREWER (cont.)

% BYPASS

This function allows adjustment of the amount of

water that bypasses the grounds. The number signi-

fies the percentage of the brew volume which does

not flow over the coffee grounds.

Modifying recipes - bypass percentages:

Range: 0% to 90% for all three batch sizes

NOTE: If the brewer is already in the % BYPASS screen,

it is not necessary to follow steps 1 through 6 in this

section, but proceed directly to step 7.

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

REVIEW RECIPES.

2. Press YES to proceed. The display should now

read NO NAME, along with MODIFY, SHOW and

NEXT.

3. Press and release NEXT to advance to the desired

REVIEW RECIPES?

NO YES

3 BATCHES DONE?

NO YES

3 BATCHES DONE?

NO YES

SET PULSE BREW?
NO YES

BREW OZ. XX.X

(-) DONE (+)

% BYPASS XX.X

(-) DONE (+)

NO-NAME

MODIFYSHOWNEXT

(COFFEE NAME)

MODIFYSHOWNEXT

THAT WAS THE

LAST RECIPE

EXIT TO

NEXT FUNCTION

SCREEN

ADVANCES TO ALL OTHER

COFFEE NAMES PROGRAMMED

IN THE BREWER'S MEMORY

WHEN THE LAST COFFEE NAME

IN THE BREWER'S MEMORY IS

DISPLAYED, PRESSING NEXT

WILL EXIT AND THE DISPLAY

WILL THEN READ:

SEE MODIFYING

PULSE BREW ON

THE FOLLOWING PAGE

OR PRESS AND RELEASE

ON/OFF PAD TO EXIT THE

% BYPASS SETUP AND

RETURN TO THE MAIN SCREEN

coffee name to be modified.

4. Press and release MODIFY. The display should

read BREW OZ.

5. Press and release DONE. The display should read

3 BATCHES DONE?.

6. Press and release YES. The display should now

read % BYPASS, and a batch light will be blinking.

Press and release the batch size to be modified.

7. Using (-) and (+) set the amount of bypass water

(percentage) to be dispensed around the grounds

for that particular batch size.

8. When finished, press another batch size and repeat

step 7 for each batch to be modified.

9. When finished setting all batch sizes, press DONE.

The display should read 3 BATCHES DONE?

10. If they are not correct, press and release NO to

return to the % BYPASS setup screen.

11. If the 3 batch sizes are correct, press YES. This will

advance to SET PULSE BREW. Another alterna-

tive is to press the ON/OFF sswitch to exit the %

BYPASS setup and return to the MAIN SCREEN.

35879.1 071405